日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  BOLD sensitivity and vessel size specificity along CPMG and GRASE echo trains

Scheffler, K., Engelmann, J., & Heule, R. (2021). BOLD sensitivity and vessel size specificity along CPMG and GRASE echo trains. Magnetic Resonance in Medicine, 86(4), 2076-2083. doi:10.1002/mrm.28871.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0008-A05D-B 版のパーマリンク: https://hdl.handle.net/21.11116/0000-000F-4204-2
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:
Not specified

作成者

表示:
非表示:
 作成者:
Scheffler, K1, 著者           
Engelmann, J1, 著者           
Heule, R2, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Institutional Guests, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_3505519              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose: To assess the vessel size specificity and sensitivity of rapid CPMG and GRASE for functional BOLD imaging for different echo train lengths, echo spacings, field strength, and refocusing flip angle schemes. In addition, the behavior of signals acquired before and after the refocusing time points is analyzed. Methods: Evolution of magnetization within a network of artificial cylinders is simulated with Monte Carlo methods for all relevant coherence pathways. In addition, measurements on microspheres were performed to confirm some of the theoretical results. Results: For reduced refocusing flip angles, the peak of the vessel size sensitivity curve is shifting toward larger radii with increasing echo time. Furthermore, the BOLD-related signal change along the echo train depends on the chosen refocusing flip angle scheme and in general does not follow corresponding echo amplitudes. Conclusion: CPMG or GRASE can be used with low refocusing flip angles without significant loss of sensitivity to BOLD. The evolution of BOLD signal changes along the echo train can be used to design optimal k-space reordering schemes. Signals acquired before or after the spin echo time point show contributions from larger vessels similar to gradient echo sequences. Short echo spacing (time between refocusing pulses) suppresses gradient echo-related contributions from larger vessels, whereas the spin echo-related contribution from small vessels remains constant and is independent of the echo spacing.

資料詳細

表示:
非表示:
言語:
 日付: 2021-052021-10
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.28871
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York : Wiley-Liss
ページ: - 巻号: 86 (4) 通巻号: - 開始・終了ページ: 2076 - 2083 識別子(ISBN, ISSN, DOIなど): ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149