Vergleichsmessungen an verschiedenen europäischen Betatronstationen / Comparative measurements at different European betatron stations

MPS-Authors
/persons/resource/persons264114

Kretschko,  Julius
Max Planck Institute of Biophysics, Max Planck Society;

/persons/resource/persons264116

Liesem,  Helmut
Max Planck Institute of Biophysics, Max Planck Society;

/persons/resource/persons263783

Pohlit,  Wolfgang
Max Planck Institute of Biophysics, Max Planck Society;

/persons/resource/persons264118

Rase,  S.
Max Planck Institute of Biophysics, Max Planck Society;

/persons/resource/persons264110

Sewkor,  Andreas
Max Planck Institute of Biophysics, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Kretschko, J., Liesem, H., Pohlit, W., Rase, S., & Sewkor, A. (1961). Vergleichsmessungen an verschiedenen europäischen Betatronstationen / Comparative measurements at different European betatron stations. Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin, 95, 553-564. doi:10.1055/s-0029-1226882.


Cite as: https://hdl.handle.net/21.11116/0000-0008-F314-F
Abstract
During a tour of European betatron stations the dosimeters used for high-energy therapy were compared with a standard dosimeter. The calibration factors for the different dosimeters in use are listed in tables. At the same time the spectral composition of the therapy beams was investigated. For this purpose the energy of the electrons was determined by measuring their range, by establishing threshold values for nuclear photo-reactions and depth dose curves in plexiglass with different energies. / Im Rahmen einer Meßreise wurden die für die Therapie mit energiereichen Strahlungen verwendeten Dosimeter an verschiedenen europäischen Betatronstationen mit einem Standardmeßgerät verglichen. Die Kalibrierungsfaktoren für die einzelnen Gebrauchsdosimeter sind in Tabellen zusammengefaßt. Gleichzeitig sollte die spektrale Zusammensetzung der zur Therapie benutzten Strahlenbündel untersucht werden. Dazu wurde die Energie der Elektronen durch Messung der Maximalreichweite bzw. der Schwellenwerte für Kernphotoreaktionen ermittelt und Tiefendosiskurven in Plexiglas bei verschiedenen Energien gemessen.