日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

 前へ次へ 
  Rapid whole-brain quantitative MT imaging

Afshari, R., Santini, F., Heule, R., Meyer, C., Pfeuffer, J., & Bieri, O. (2023). Rapid whole-brain quantitative MT imaging. Zeitschrift für Medizinische Physik, Epub ahead. doi:10.1016/j.zemedi.2023.02.005.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-000C-EC67-7 版のパーマリンク: https://hdl.handle.net/21.11116/0000-000F-41F0-8
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:
Not specified

作成者

表示:
非表示:
 作成者:
Afshari, R, 著者
Santini, F, 著者
Heule, R1, 著者                 
Meyer, CH, 著者
Pfeuffer, J, 著者           
Bieri, O, 著者
所属:
1Institutional Guests, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_3505519              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose: To provide a robust whole-brain quantitative magnetization transfer (MT) imaging method that is not limited by long acquisition times.
Methods: Two variants of a spiral 2D interleaved multi-slice spoiled gradient echo (SPGR) sequence are used for rapid quantitative MT imaging of the brain at 3 T. A dual flip angle, steady-state prepared, double-contrast method is used for combined B1 and-T1 mapping in combination with a single-contrast MT-prepared acquisition over a range of different saturation flip angles (50 deg to 850 deg) and offset frequencies (1 kHz and 10 kHz). Five sets (containing minimum 6 to maximum 18 scans) with different MT-weightings were acquired. In addition, main magnetic field inhomogeneities (ΔB0) were measured from two Cartesian low-resolution 2D SPGR scans with different echo times. Quantitative MT model parameters were derived from all sets using a two-pool continuous-wave model analysis, yielding the pool-size ratio, F, their exchange rate, kf, and their transverse relaxation time, T2r.
Results: Whole-brain quantitative MT imaging was feasible for all sets with total acquisition times ranging from 7:15 min down to 3:15 min. For accurate modeling, B1-correction was essential for all investigated sets, whereas ΔB0-correction showed limited bias for the observed maximum off-resonances at 3 T.
Conclusion: The combination of rapid B1-T1 mapping and MT-weighted imaging using a 2D multi-slice spiral SPGR research sequence offers excellent prospects for rapid whole-brain quantitative MT imaging in the clinical setting.

資料詳細

表示:
非表示:
言語:
 日付: 2023-04
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1016/j.zemedi.2023.02.005
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Zeitschrift für Medizinische Physik
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Jena [Germany] : Urban & Fischer
ページ: - 巻号: Epub ahead 通巻号: - 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): ISSN: 0939-3889
CoNE: https://pure.mpg.de/cone/journals/resource/110978984077161