Polarimetric calibration of a spectropolarimeter instrument with high precision: Sunrise chromospheric infrared spectropolarimeter (SCIP) for the sunrise iii balloon telescope

MPG-Autoren
/persons/resource/persons103917

Gandorfer,  Achim
Department Sun and Heliosphere, Max Planck Institute for Solar System Research, Max Planck Society;

/persons/resource/persons103910

Feller,  Alex
Department Sun and Heliosphere, Max Planck Institute for Solar System Research, Max Planck Society;

Externe Ressourcen
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Kawabata, Y., Katsukawa, Y., Kubo, M., Anan, T., Ichimoto, K., Shinoda, K., et al. (2022). Polarimetric calibration of a spectropolarimeter instrument with high precision: Sunrise chromospheric infrared spectropolarimeter (SCIP) for the sunrise iii balloon telescope. Applied Optics, 61, 9716. doi:10.1364/AO.472516.


Zitierlink: https://hdl.handle.net/21.11116/0000-000D-B848-3
Zusammenfassung
The Sunrise chromospheric infrared spectropolarimeter (SCIP) installed in the international balloon experiment sunrise iii will perform spectropolarimetric observations in the near-infrared band to measure solar photospheric and chromospheric magnetic fields simultaneously. The main components of SCIP for polarization measurements are a rotating wave plate, polarization beam splitters, and CMOS imaging sensors. In each of the sensors, SCIP records the orthogonal linearly polarized components of light. The polarization is later demodulated on-board. Each sensor covers one of the two distinct wavelength regions centered at 770 and 850 nm. To retrieve the proper circular polarization, the new parameter R , defined as the 45° phase shifted component of Stokes V in the modulation curve, is introduced. SCIP is aimed at achieving high polarization precision ( 1 σ < 3 × 10 − 4 of continuum intensity) to capture weak polarization signals in the chromosphere. The objectives of the polarization calibration test presented in this paper are to determine a response matrix of SCIP and to measure its repeatability and temperature dependence to achieve the required polarization precision. Tolerances of the response matrix elements were set after considering typical photospheric and chromospheric polarization signal levels. We constructed a feed optical system such that a telecentric beam can enter SCIP with the same f -number as the light distribution instrument of the sunrise iii telescope. A wire-grid linear polarizer and achromatic wave plate were placed before SCIP to produce the known polarization. The obtained response matrix was close to the values expected from the design. The wavelength and spatial variations, repeatability, and temperature dependence of the response matrix were confirmed to be smaller than tolerances.