- HideElectronic Supporting Information files are available without a subscription to ACS Web Editions. The American Chemical Society holds a copyright ownership interest in any copyrightable Supporting Information. Files available from the ACS website may be downloaded for personal use only. Users are not otherwise permitted to reproduce, republish, redistribute, or sell any Supporting Information from the ACS website, either in whole or in part, in either machine-readable form or any other form without permission from the American Chemical Society. For permission to reproduce, republish and redistribute this material, requesters must process their own requests via the RightsLink permission system. Information about how to use the RightsLink permission system can be found at http://pubs.acs.org/page/copyright/permissions.html.
Integrated Measurement of the Mass and Surface Charge of Discrete Microparticles Using a Suspended Microchannel Resonator
Department of Biological Engineering.
, ‡Department of Mechanical Engineering.
Abstract
Measurements of the mass and surface charge of microparticles are employed in the characterization of many types of colloidal dispersions. The suspended microchannel resonator (SMR) is capable of measuring individual particle masses with femtogram resolution. Here, we employ the high sensitivity of the SMR resonance frequency to changes in particle position, relative to the cantilever tip, to determine the electrophoretic mobility of discrete particles in an applied electric field. When a sinusoidal electric field is applied to the suspended microchannel, the transient resonance frequency shift corresponding to a particle transit can be analyzed by digital signal processing to extract both the buoyant mass and electrophoretic mobility of each particle. These parameters, together with the mean particle density, can be used to compute the size, absolute mass, and surface charge of discrete microspheres, leading to a true representation of the mean and polydispersity of these quantities for a population. We have applied this technique to an aqueous suspension of two types of polystyrene microspheres, to differentiate them based on their absolute mass and their surface charge. The integrated measurement of electrophoretic mobility using the SMR is determined to be quantitative, based on comparison with commercial instruments, and exhibits favorable scaling properties that will ultimately enable measurements from mammalian cells.
Citing Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 2 ACS Journal articles (2 most recent appear below).
Liquid-Phase Chemical Sensing Using Lateral Mode Resonant Cantilevers
L.A. Beardslee, K.S. Demirci, Y. Luzinova, B. Mizaikoff, S.M. Heinrich, F. Josse, and O. BrandAnalytical Chemistry2010 82 (18), 7542-7549Liquid-Phase Chemical Sensing Using Lateral Mode Resonant Cantilevers
L.A. Beardslee, K.S. Demirci, Y. Luzinova, B. Mizaikoff, S.M. Heinrich, F. Josse, and O. BrandAnalytical Chemistry2010 82 (18), 7542-7549Liquid-phase operation of resonant cantilevers vibrating in an out-of-plane flexural mode has to date been limited by the considerable fluid damping and the resulting low quality factors (Q factors). To reduce fluid damping in liquids and to improve the ...
Magnetic Levitation in the Analysis of Foods and Water
Katherine A. Mirica, Scott T. Phillips, Charles R. Mace and George M. WhitesidesJournal of Agricultural and Food Chemistry2010 58 (11), 6565-6569Magnetic Levitation in the Analysis of Foods and Water
Katherine A. Mirica, Scott T. Phillips, Charles R. Mace and George M. WhitesidesJournal of Agricultural and Food Chemistry2010 58 (11), 6565-6569This paper describes a method and a sensor that use magnetic levitation (MagLev) to characterize samples of food and water on the basis of measurements of density. The sensor comprises two permanent NdFeB magnets positioned on top of each other in a ...
Tools
- Add to Favorites
- Download Citation
- Email a Colleague
- Permalink
- Order Reprints
- Rights & Permissions
- Citation Alerts
History
- Published In Issue June 01, 2009
- Article ASAPMay 08, 2009
- Received: March 10, 2009
Accepted: April 23, 2009