Sensors 2019, 19(9), 2065; https://doi.org/10.3390/s19092065 (registering DOI)
Robust Smartphone Assisted Biosensing Based on Asymmetric Nanofluidic Grating Interferometry
1
Institute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany
2
Max-Planck Institute for Biophysical Chemistry, 37077 Göttingen, Germany
3
Department of Electrical Engineering and Information Technology, Technische Universität Darmstadt, 64283 Darmstadt, Germany
*
Author to whom correspondence should be addressed.
†
Current address: Institute of Microtechnology, Technische Universität Braunschweig, Alte Salzdahlumerstraße 203, 38124 Braunschweig, Germany.
‡
These authors contributed equally to this work.
Received: 28 March 2019 / Revised: 23 April 2019 / Accepted: 25 April 2019 / Published: 3 May 2019
(This article belongs to the Special Issue Portable Biosensing Systems for Point-of-Care Diagnostic Applications)
Abstract
Point-of-care systems enable fast therapy decisions on site without the need of any healthcare infrastructure. In addition to the sensitive detection, stable measurement by inexperienced persons outside of laboratory facilities is indispensable. A particular challenge in field applications is to reduce interference from environmental factors, such as temperature, to acceptable levels without sacrificing simplicity. Here, we present a smartphone-based point-of-care sensor. The method uses an optofluidic grating composed of alternating detection and reference channels arranged as a reflective phase grating. Biomolecules adsorbing to the detection channel alter the optical path length, while the parallel reference channels enable a direct common mode rejection within a single measurement. The optical setup is integrated in a compact design of a mobile readout device and the usability is ensured by a smartphone application. Our results show that different ambient temperatures do not have any influence on the signal. In a proof-of concept experiment we measured the accumulation of specific molecules in functionalized detection channels in real-time and without the need of any labeling. Therefore, the channel walls have been modified with biotin as capture molecules and the specific binding of streptavidin was detected. A mobile, reliable and robust point-of-care device has been realized by combining an inherently differential measurement concept with a smartphone-based, mobile readout device. View Full-TextKeywords:
biosensing; interferometry; portable point-of-care (POC); common mode rejection; nanofluidic; optofluidic grating; smartphone-based
▼
Figures
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0).
Share & Cite This Article
MDPI and ACS Style
Purr, F.; Eckardt, M.-F.; Kieserling, J.; Gronwald, P.-L.; Burg, T.P.; Dietzel, A. Robust Smartphone Assisted Biosensing Based on Asymmetric Nanofluidic Grating Interferometry. Sensors 2019, 19, 2065.
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.