Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Mechanical Q-factor measurements on a test mass with a structured surface

Nawrodt, R., Zimmer, A., Koettig, T., Clausnitzer, T., Bunkowski, A., Kley, E.-B., et al. (2007). Mechanical Q-factor measurements on a test mass with a structured surface. New Journal of Physics, 9: 225. doi:10.1088/1367-2630/9/7/225.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
njp7_7_225.pdf (Verlagsversion), 369KB
Name:
njp7_7_225.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Nawrodt, Ronny, Autor
Zimmer, A., Autor
Koettig, Torsten, Autor
Clausnitzer, Tina, Autor
Bunkowski, Alexander1, 2, Autor
Kley, Ernst-Bernhard, Autor
Schnabel, Roman1, Autor           
Danzmann, Karsten1, Autor           
Vodel, W., Autor
Tünnermann, Andreas1, 2, Autor
Seidel, Paul, Autor
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              
2AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24009              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: We present mechanical Q-factors (quality factors) of a crystalline quartz test mass with a nano-structured surface, measured in the temperature regime from 5 to 300 K. The nano-structure was a grating with a period of 2 μm and a depth of about 0.1 μm. Comparative measurements were performed on the plain substrate and on the structured test mass with different numbers of SiO2/Ta2O5 coating layers. The measurements at different stages of the test mass fabrication process show that the surface distortion induced by the nanostructure does not severely lower the mechanical Q-factor of the substrate. Damping due to a multi-layer coating stack was found to be orders of magnitude higher. The results provide vital information concerning the potential usage of low-thermal noise nano-structured test masses in future generations of high-precision laser interferometers and in current attempts to measure quantum effects of macroscopic mirror oscillators.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2007
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 318080
DOI: 10.1088/1367-2630/9/7/225
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: New Journal of Physics
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 9 Artikelnummer: 225 Start- / Endseite: - Identifikator: -