  Maintaining high precision of isotope ratio analysis over extended periods of time

Brand, W. A. (2009). Maintaining high precision of isotope ratio analysis over extended periods of time. Isotopes in Environmental and Health Studies, 45(2), 135-149. doi:10.1080/10256010902869097.

Item is

Files

show Files
hide Files
:
BGC1289.pdf (Publisher version), 672KB
 
File Permalink:
-
Name:
BGC1289.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Type / Checksum:
application/octet-stream
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Brand, Willi A.1, Author           
Affiliations:
1Service Facility Stable Isotope, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497772              

Content

show
hide
Free keywords: carbon-13 isotope measurement methods and equipment IAEA measurement strategy nitrogen-15 reference materials reliability of data
 Abstract: Stable isotope ratios are reliable and long lasting process tracers. In order to compare data from different locations or different sampling times at a high level of precision, a measurement strategy must include reliable traceability to an international stable isotope scale via a reference material (RM). Since these international RMs are available in low quantities only, we have developed our own analysis schemes involving laboratory working RM. In addition, quality assurance RMs are used to control the long-term performance of the delta-value assignments. The analysis schemes allow the construction of quality assurance performance charts over years of operation. In this contribution, the performance of three typical techniques established in IsoLab at the MPI-BGC in Jena is discussed. The techniques are (1) isotope ratio mass spectrometry with an elemental analyser for delta N-15 and delta C-13 analysis of bulk (organic) material, (2) high precision delta C-13 and delta O-18 analysis of CO2 in clean-air samples, and (3) stable isotope analysis of water samples using a high-temperature reaction with carbon. In addition, reference strategies on a laser ablation system for high spatial resolution delta C-13 analysis in tree rings is exemplified briefly.

Details

show
hide
Language(s): eng - English
 Dates: 2009
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1080/10256010902869097
ISI: ://000268612600006
Other: BGC1289
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Isotopes in Environmental and Health Studies
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Reading, Berkshire [u.a.] : Gordon and Breach Publishers
Pages: - Volume / Issue: 45 (2) Sequence Number: - Start / End Page: 135 - 149 Identifier: ISSN: 1025-6016
CoNE: https://pure.mpg.de/cone/journals/resource/954926944750