Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Model-based reconstruction for real-time phase-contrast flow MRI: Improved spatiotemporal accuracy.

Tan, Z., Roeloffs, V. B., Voit, D., Joseph, A. A., Untenberger, M., Merboldt, K. D., et al. (2017). Model-based reconstruction for real-time phase-contrast flow MRI: Improved spatiotemporal accuracy. Magnetic Resonance in Medicine, 77(3), 1082-1093. doi:10.1002/mrm.26192.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2351084.pdf (Verlagsversion), 2MB
 
Datei-Permalink:
-
Name:
2351084.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2351084_Suppl_1.avi (Ergänzendes Material), 761KB
Name:
2351084_Suppl_1.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2351084_Suppl_2.avi (Ergänzendes Material), 490KB
Name:
2351084_Suppl_2.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2351084_Suppl_3.avi (Ergänzendes Material), 893KB
Name:
2351084_Suppl_3.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2351084_Suppl_4.avi (Ergänzendes Material), 443KB
Name:
2351084_Suppl_4.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2351084_Suppl_5.avi (Ergänzendes Material), 2MB
Name:
2351084_Suppl_5.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2351084_Suppl_6.avi (Ergänzendes Material), 525KB
Name:
2351084_Suppl_6.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Tan, Z.1, Autor           
Roeloffs, V. B.1, Autor           
Voit, D.1, Autor           
Joseph, A. A.1, Autor           
Untenberger, M.1, Autor           
Merboldt, K. D.1, Autor           
Frahm, J.1, Autor           
Affiliations:
1Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society, ou_578634              

Inhalt

einblenden:
ausblenden:
Schlagwörter: nonlinear inverse reconstruction; model-based reconstruction; cardiovascular blood flow; phase-contrast flow MRI; radial MRI; real-time MRI
 Zusammenfassung: PURPOSE: To develop a model-based reconstruction technique for real-time phase-contrast flow MRI with improved spatiotemporal accuracy in comparison to methods using phase differences of two separately reconstructed images with differential flow encodings. METHODS: The proposed method jointly computes a common image, a phase-contrast map, and a set of coil sensitivities from every pair of flow-compensated and flow-encoded datasets obtained by highly undersampled radial FLASH. Real-time acquisitions with five and seven radial spokes per image resulted in 25.6 and 35.7 ms measuring time per phase-contrast map, respectively. The signal model for phase-contrast flow MRI requires the solution of a nonlinear inverse problem, which is accomplished by an iteratively regularized Gauss-Newton method. Aspects of regularization and scaling are discussed. The model-based reconstruction was validated for a numerical and experimental flow phantom and applied to real-time phase-contrast MRI of the human aorta for 10 healthy subjects and 2 patients. RESULTS: Under all conditions, and compared with a previously developed real-time flow MRI method, the proposed method yields quantitatively accurate phase-contrast maps (i.e., flow velocities) with improved spatial acuity, reduced phase noise and reduced streaking artifacts. CONCLUSION: This novel model-based reconstruction technique may become a new tool for clinical flow MRI in real time.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2016-03-072017-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.26192
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 77 (3) Artikelnummer: - Start- / Endseite: 1082 - 1093 Identifikator: -