English
 
User Manual Privacy Policy Disclaimer Contact us
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  19F-Lanthanide Complexes: T1 - And T2 - Dependent Signal Gain Using Gradient Echoes

Hagberg, G., Keliris, A., Mamedov, I., Placidi, M., Merkle, H., Logothetis, N., et al. (2013). 19F-Lanthanide Complexes: T1 - And T2 - Dependent Signal Gain Using Gradient Echoes. Poster presented at 21st Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2013), Salt Lake City, UT, USA.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/21.11116/0000-0001-55AD-D Version Permalink: http://hdl.handle.net/21.11116/0000-0001-55AE-C
Genre: Poster

Files

show Files

Locators

show
hide
Locator:
https://www.ismrm.org/13/tp07.htm (Abstract)
Description:
-

Creators

show
hide
 Creators:
Hagberg, G, Author              
Keliris, A1, 2, Author              
Mamedov, I2, 3, Author              
Placidi, M, Author
Merkle, H, Author              
Logothetis, NK2, 3, Author              
Scheffler, K1, 2, Author              
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              

Content

show
hide
Free keywords: -
 Abstract: 19F-labelled compounds have unique benefits for biological applications but are hampered by low sensitivity. Lanthanide-complexes that shorten the 19F T1 and T2 relaxation times can boost the SNR in spoiled gradient echo sequences (FLASH). We investigated the MRI signal systematically for a wide range of T1 and T2 times for FLASH and balanced steady state free precession (tFISP). For long T2 times the tFISP signal is always greater, and for short relaxation times the signal gain depends on the duration of encoding and spoiling. None of the available compounds had ‘ideal’ relaxation times that gives the highest possible signal. Our results can be used to design better 19F contrast agents tailored to a specific MRI sequence.

Details

show
hide
Language(s):
 Dates: 2013-04
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Method: -
 Identifiers: -
 Degree: -

Event

show
hide
Title: 21st Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2013)
Place of Event: Salt Lake City, UT, USA
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: 21st Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2013)
Source Genre: Proceedings
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: 1891 Start / End Page: - Identifier: -