Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  19F-Lanthanide Complexes: T1 - And T2 - Dependent Signal Gain Using Gradient Echoes

Hagberg, G., Keliris, A., Mamedov, I., Placidi, M., Merkle, H., Logothetis, N., et al. (2013). 19F-Lanthanide Complexes: T1 - And T2 - Dependent Signal Gain Using Gradient Echoes. Poster presented at 21st Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2013), Salt Lake City, UT, USA.

Item is

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
https://www.ismrm.org/13/tp07.htm (Zusammenfassung)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Hagberg, G, Autor           
Keliris, A1, 2, Autor           
Mamedov, I2, 3, Autor           
Placidi, M, Autor
Merkle, H, Autor           
Logothetis, NK2, 3, Autor           
Scheffler, K1, 2, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: 19F-labelled compounds have unique benefits for biological applications but are hampered by low sensitivity. Lanthanide-complexes that shorten the 19F T1 and T2 relaxation times can boost the SNR in spoiled gradient echo sequences (FLASH). We investigated the MRI signal systematically for a wide range of T1 and T2 times for FLASH and balanced steady state free precession (tFISP). For long T2 times the tFISP signal is always greater, and for short relaxation times the signal gain depends on the duration of encoding and spoiling. None of the available compounds had ‘ideal’ relaxation times that gives the highest possible signal. Our results can be used to design better 19F contrast agents tailored to a specific MRI sequence.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2013-04
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: -
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 21st Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2013)
Veranstaltungsort: Salt Lake City, UT, USA
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 21st Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2013)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: 1891 Start- / Endseite: - Identifikator: -