  A liquid flow cell to study the electronic structure of liquids with soft X-rays

Fuchsa, O., Maier, F., Weinhardt, L., Weigand, M., Blum, M., Zharnikov, M., et al. (2008). A liquid flow cell to study the electronic structure of liquids with soft X-rays. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 585(3), 172-177. doi:10.1016/j.nima.2007.10.029.

Item is

Files

show Files
hide Files
:
NuclearInstrMethPhysResA_585_2008_172.pdf (Any fulltext), 231KB
 
File Permalink:
-
Name:
NuclearInstrMethPhysResA_585_2008_172.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Medical Research, MHMF; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Creators

show
hide
 Creators:
Fuchsa, Oliver, Author
Maier, Florian, Author
Weinhardt, Lothar, Author
Weigand, Markus, Author
Blum, Monika, Author
Zharnikov, Michael, Author
Denlinger, Jonathan, Author
Grunze, Michael1, Author           
Heske, Clemens, Author
Umbach, Eberhard, Author
Affiliations:
1Cellular Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_2364731              

Content

show
hide
Free keywords: Liquid cell; Water; Soft X-ray spectroscopy; X-ray absorption; X-ray emission
 Abstract: We describe the design of a temperature-controlled flow-through liquid cell dedicated to the study of liquids with soft X-rays. The cell can be operated with internal ambient pressure and is mounted on a standard vacuum manipulator, making it compatible to the ultra-high vacuum environment required in synchrotron beamlines. The liquid is separated from the vacuum by a thin membrane, allowing the use of soft X-ray photon-in–photon-out techniques such as X-ray emission and fluorescence-yield X-ray absorption spectroscopy to study the electronic structure of liquids and liquid–solid interfaces. Special care was taken for a rapid and effective flow of the liquid inside the cell in order to minimize local heating and beam damage effects. To illustrate the capabilities, oxygen K X-ray emission spectra of D2O and H2O are presented and briefly discussed together with possible problems that may arise from X-ray-induced oxide formation at the membrane–liquid interface.

Details

show
hide
Language(s): eng - English
 Dates: 2007-08-162007-10-172007-10-232008-02-01
 Publication Status: Issued
 Pages: 6
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.nima.2007.10.029
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier B.V.
Pages: - Volume / Issue: 585 (3) Sequence Number: - Start / End Page: 172 - 177 Identifier: ISSN: 0168-9002
CoNE: https://pure.mpg.de/cone/journals/resource/954925485716