Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Calibrating rhythmic stimulation parameters to individual electroencephalography markers: The consistency of individual alpha frequency in practical lab settings

Janssens, S. E. W., Sack, A. T., Ten Oever, S., & Graaf, T. A. (2022). Calibrating rhythmic stimulation parameters to individual electroencephalography markers: The consistency of individual alpha frequency in practical lab settings. European Journal of Neuroscience, 55(11/12), 3418-3437. doi:10.1111/ejn.15418.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Janssens_etal_2021_Calibrating rhythmic stimulation parameters....pdf (Verlagsversion), 3MB
Name:
Janssens_etal_2021_Calibrating rhythmic stimulation parameters....pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
2021
Copyright Info:
© 2021 The Authors. European Journal of Neuroscience published by Federation of European Neuroscience Societies and John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
:
Janssens_etal_2021suppl_Calibrating rhythmic stimulation parameters....pdf (Ergänzendes Material), 2MB
Name:
supporting information
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
Janssens_etal_2022_calibrating rhythmic stimulation....pdf (Verlagsversion), 10MB
Name:
Janssens_etal_2022_calibrating rhythmic stimulation....pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
2021
Copyright Info:
© 2021 The Authors. European Journal of Neuroscience published by Federation of European Neuroscience Societies and John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
data and analysis code (Ergänzendes Material)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Janssens, Shanice E. W.1, Autor
Sack, Alexander T.1, Autor
Ten Oever, Sanne1, 2, 3, Autor           
Graaf, Tom A.1, Autor
Affiliations:
1Maastricht University, Maastricht, The Netherlands, ou_persistent22              
2Language and Computation in Neural Systems, MPI for Psycholinguistics, Max Planck Society, ou_3217300              
3FC Donders Centre for Cognitive Neuroimaging , External Organizations, ou_55235              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Rhythmic stimulation can be applied to modulate neuronal oscillations. Such ‘entrainment’ is optimized when stimulation frequency is individually calibrated based on magneto/encephalography markers. It remains unknown how consistent such individual markers are across days/sessions, within a session, or across cognitive states, hemispheres and estimation methods, especially in a realistic, practical, lab setting. We here estimated individual alpha frequency (IAF) repeatedly from short electroencephalography (EEG) measurements at rest or during an attention task (cognitive state), using single parieto-occipital electrodes in 24 participants on 4 days (between-sessions), with multiple measurements over an hour on 1 day (within-session). First, we introduce an algorithm to automatically reject power spectra without a sufficiently clear peak to ensure unbiased IAF estimations. Then we estimated IAF via the traditional ‘maximum’ method and a ‘Gaussian fit’ method. IAF was reliable within- and between-sessions for both cognitive states and hemispheres, though task-IAF estimates tended to be more variable. Overall, the ‘Gaussian fit’ method was more reliable than the ‘maximum’ method. Furthermore, we evaluated how far from an approximated ‘true’ task-related IAF the selected ‘stimulation frequency’ was, when calibrating this frequency based on a short rest-EEG, a short task-EEG, or simply selecting 10 Hz for all participants. For the ‘maximum’ method, rest-EEG calibration was best, followed by task-EEG, and then 10 Hz. For the ‘Gaussian fit’ method, rest-EEG and task-EEG-based calibration were similarly accurate, and better than 10 Hz. These results lead to concrete recommendations about valid, and automated, estimation of individual oscillation markers in experimental and clinical settings.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2021-09-052022
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1111/ejn.15418
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: European Journal of Neuroscience
  Andere : Eur. J. Neurosci
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 55 (11/12) Artikelnummer: - Start- / Endseite: 3418 - 3437 Identifikator: ISSN: 0953-816X
CoNE: https://pure.mpg.de/cone/journals/resource/954925575988