Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Axial motion estimation and correction for simultaneous multi-plane two-photon calcium imaging

Flores Valle, A., & Seelig, J. D. (2022). Axial motion estimation and correction for simultaneous multi-plane two-photon calcium imaging. Biomedical Optics Express, 13(4), 2035-2049. doi:10.1364/BOE.445775.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
5691791.pdf (Ergänzendes Material), 4MB
Name:
5691791.pdf
Beschreibung:
-
OA-Status:
Keine Angabe
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
2022
Copyright Info:
-
:
boe-13-4-2035.pdf (Verlagsversion), 12MB
Name:
boe-13-4-2035.pdf
Beschreibung:
-
OA-Status:
Keine Angabe
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
2022
Copyright Info:
-

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:
Keine Angabe

Urheber

einblenden:
ausblenden:
 Urheber:
Flores Valle, Andres1, 2, Autor                 
Seelig, Johannes D.1, Autor                 
Affiliations:
1Max Planck Research Group Neural Circuits, Max Planck Institute for Neurobiology of Behavior – caesar, Max Planck Society, ou_3361780              
2International Max Planck Research School (IMPRS) for Brain and Behavior, Max Planck Institute for Neurobiology of Behavior – caesar, Max Planck Society, ou_3481421              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Two-photon imaging in behaving animals is typically accompanied by brain motion. For functional imaging experiments, for example with genetically encoded calcium indicators, such brain motion induces changes in fluorescence intensity. These motion-related intensity changes or motion artifacts can typically not be separated from neural activity-induced signals. While lateral motion, within the focal plane, can be corrected by computationally aligning images, axial motion, out of the focal plane, cannot easily be corrected. Here, we developed an algorithm for axial motion correction for non-ratiometric calcium indicators taking advantage of simultaneous multi-plane imaging. Using temporally multiplexed beams, recording simultaneously from at least two focal planes at different z positions, and recording a z-stack for each beam as a calibration step, the algorithm separates motion-related and neural activity-induced changes in fluorescence intensity. The algorithm is based on a maximum likelihood optimisation approach; it assumes (as a first order approximation) that no distortions of the sample occurs during axial motion and that neural activity increases uniformly along the optical axis in each region of interest. The developed motion correction approach allows axial motion estimation and correction at high frame rates for isolated structures in the imaging volume in vivo, such as sparse expression patterns in the fruit fly brain.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2022
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1364/BOE.445775
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Biomedical Optics Express
  Kurztitel : Biomed Opt Express
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Washington, DC : Optical Society of America (OSA)
Seiten: - Band / Heft: 13 (4) Artikelnummer: - Start- / Endseite: 2035 - 2049 Identifikator: CoNE: https://pure.mpg.de/cone/journals/resource/2156-7085