Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Fiber-orientation independent component of R2* obtained from single-orientation MRI measurements in simulations and a post-mortem human optic chiasm

Fritz, F. J., Mordhorst, L., Ashtarayeh, M., Periquito, J., Pohlmann, A., Morawski, M., et al. (2023). Fiber-orientation independent component of R2* obtained from single-orientation MRI measurements in simulations and a post-mortem human optic chiasm. Frontiers in Neuroscience, 17: 1133086. doi:10.3389/fnins.2023.1133086.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Fritz_2023.pdf (Verlagsversion), 4MB
Name:
Fritz_2023.pdf
Beschreibung:
-
OA-Status:
Gold
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Fritz, Francisco J.1, Autor
Mordhorst, Laurin1, Autor
Ashtarayeh, Mohammad1, Autor
Periquito, Joao2, Autor
Pohlmann, Andreas2, Autor
Morawski, Markus3, 4, Autor                 
Jäger, Carsten3, 4, Autor                 
Niendorf, Thoralf2, Autor
Pine, Kerrin4, Autor                 
Callaghan, Martina F.5, Autor
Weiskopf, Nikolaus4, 6, Autor                 
Mohammadi, Siawoosh1, 4, 7, Autor           
Affiliations:
1Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Germany, ou_persistent22              
2Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine, Berlin, Germany, ou_persistent22              
3Paul Flechsig Institute for Brain Research, University of Leipzig, Germany, ou_persistent22              
4Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              
5Wellcome Trust Centre for Neuroimaging, Institute of Neurology, University College London, United Kingdom, ou_persistent22              
6Felix Bloch Institute for Solid State Physics, University of Leipzig, Germany, ou_persistent22              
7Max Planck Research Group MR Physics, Max Planck Institute for Human Development, Berlin, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: R2*; Biophysical model; Effective transverse relaxation rate; Fibre dispersion; g-ratio; Multi-echo gradient recalled echo; Myelin water fraction; Orientation-independent R2*
 Zusammenfassung: The effective transverse relaxation rate (R2*) is sensitive to the microstructure of the human brain like the g-ratio which characterises the relative myelination of axons. However, the fibre-orientation dependence of R2* degrades its reproducibility and any microstructural derivative measure. To estimate its orientation-independent part (R2,iso*) from single multi-echo gradient-recalled-echo (meGRE) measurements at arbitrary orientations, a second-order polynomial in time model (hereafter M2) can be used. Its linear time-dependent parameter, β1, can be biophysically related to R2,iso* when neglecting the myelin water (MW) signal in the hollow cylinder fibre model (HCFM). Here, we examined the performance of M2 using experimental and simulated data with variable g-ratio and fibre dispersion. We found that the fitted β1 can estimate R2,iso* using meGRE with long maximum-echo time (TEmax ≈ 54 ms), but not accurately captures its microscopic dependence on the g-ratio (error 84%). We proposed a new heuristic expression for β1 that reduced the error to 12% for ex vivo compartmental R2 values. Using the new expression, we could estimate an MW fraction of 0.14 for fibres with negligible dispersion in a fixed human optic chiasm for the ex vivo compartmental R2 values but not for the in vivo values. M2 and the HCFM-based simulations failed to explain the measured R2*-orientation-dependence around the magic angle for a typical in vivo meGRE protocol (with TEmax ≈ 18 ms). In conclusion, further validation and the development of movement-robust in vivo meGRE protocols with TEmax ≈ 54 ms are required before M2 can be used to estimate R2,iso* in subjects.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2022-12-282023-08-242023-08-25
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.3389/fnins.2023.1133086
Anderer: eCollection 2023
PMID: 37694109
PMC: PMC10491021
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden: ausblenden:
Projektname : -
Grant ID : AL 1156/2-1;GE 2967/1-1; MO 2397/5-1; MO 2249/3-1; MO 2397/5-2; MO 2397/4-1; MO 2397/4-2
Förderprogramm : -
Förderorganisation : German Research Foundation (DFG)
Projektname : -
Grant ID : 01EW1711A and B
Förderprogramm : -
Förderorganisation : Bundesministerium für Bildung und Forschung (BMBF)
Projektname : -
Grant ID : 01fmthh2017
Förderprogramm : -
Förderorganisation : Forschungszentrums Medizintechnik Hamburg (FMTHH)
Projektname : -
Grant ID : 616,905
Förderprogramm : -
Förderorganisation : European Union
Projektname : -
Grant ID : MR/R000050/1
Förderprogramm : -
Förderorganisation : Medical Research Council (MRC)
Projektname : -
Grant ID : 203,147/Z/16/Z
Förderprogramm : -
Förderorganisation : Wellcome Centre for Human Neuroimaging

Quelle 1

einblenden:
ausblenden:
Titel: Frontiers in Neuroscience
  Andere : Front Neurosci
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Lausanne, Switzerland : Frontiers Research Foundation
Seiten: - Band / Heft: 17 Artikelnummer: 1133086 Start- / Endseite: - Identifikator: ISSN: 1662-4548
ISSN: 1662-453X
CoNE: https://pure.mpg.de/cone/journals/resource/1662-4548