日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  FastPtx: a versatile toolbox for rapid, joint design of pTx RF and gradient pulses using Pytorch's autodifferentiation

Bosch, D., & Scheffler, K. (2024). FastPtx: a versatile toolbox for rapid, joint design of pTx RF and gradient pulses using Pytorch's autodifferentiation. Magnetic Resonance Materials in Physics, Biology and Medicine, 37(1), 127-138. doi:10.1007/s10334-023-01134-7.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-000E-0681-9 版のパーマリンク: https://hdl.handle.net/21.11116/0000-000E-7389-6
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:
Not specified

作成者

表示:
非表示:
 作成者:
Bosch, D1, 著者                 
Scheffler, K1, 著者                 
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Objective: With modern optimization methods, free optimization of parallel transmit pulses together with their gradient waveforms can be performed on-line within a short time. A toolbox which uses PyTorch's autodifferentiation for simultaneous optimization of RF and gradient waveforms is presented and its performance is evaluated.
Methods: MR measurements were performed on a 9.4T MRI scanner using a 3D saturated single-shot turboFlash sequence for [Formula: see text] mapping. RF pulse simulation and optimization were done using a Python toolbox and a dedicated server. An RF- and Gradient pulse design toolbox was developed, including a cost function to balance different metrics and respect hardware and regulatory limits. Pulse performance was evaluated in GRE and MPRAGE imaging. Pulses for non-selective and for slab-selective excitation were designed.
Results: Universal pulses for non-selective excitation reduced the flip angle error to an NRMSE of (12.3±1.7)% relative to the targeted flip angle in simulations, compared to (42.0±1.4)% in CP mode. The tailored pulses performed best, resulting in a narrow flip angle distribution with NRMSE of (8.2±1.0)%. The tailored pulses could be created in only 66 s, making it feasible to design them during an experiment. A 90° pulse was designed as preparation pulse for a satTFL sequence and achieved a NRMSE of 7.1%. We showed that both MPRAGE and GRE imaging benefited from the pTx pulses created with our toolbox.
Conclusion: The pTx pulse design toolbox can freely optimize gradient and pTx RF waveforms in a short time. This allows for tailoring high-quality pulses in just over a minute.

資料詳細

表示:
非表示:
言語:
 日付: 2023-122024-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/s10334-023-01134-7
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
  省略形 : MAGMA
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : No longer published by Elsevier
ページ: - 巻号: 37 (1) 通巻号: - 開始・終了ページ: 127 - 138 識別子(ISBN, ISSN, DOIなど): ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532