English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal

MPS-Authors
/persons/resource/persons62384

Gleixner,  G.
Molecular Biogeochemistry Group, Dr. G. Gleixner, Department Biogeochemical Processes, Prof. E.-D. Schulze, Max Planck Institute for Biogeochemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Vetter, W., Schlatterer, J., & Gleixner, G. (2006). Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal. Journal of Chromatography A, 1110(1-2), 165-170.


Cite as: https://hdl.handle.net/11858/00-001M-0000-000E-D4AD-7
Abstract
The carbon stable isotope ratio (delta C-13 value) of an environmentally-relevant Toxaphene congener in technical products and a biological sample from a remote region was in the focus of this work. For this reason, the major octachlorobornane residue of the multicomponent pesticide Toxaphene in biological samples, 2-endo,3-exo,5-endo,6-exo,8,8,10,10-octachlorobornane (B8-1413 or P26), was quantitatively enriched from two technical Toxaphene mixtures (Toxaphene and Melipax) in duplicates as well as from an Antarctic Weddell seal sample. Normal phase followed by reversed-phase high-performance liquid chromatography (HPLC) with three columns, respectively, coupled in series was used for this purpose. Four of the five fractionated samples fulfilled the requirement of an interference-free GC-elution for subsequent determination of the delta C-13 value by gas chromatography interfaced to an isotope ratio mass spectrometer (GC-IRMS). B8-1413 in Toxaphene (n = 1) was more depleted in C-12 than in Melipax (n = 2), which agrees with previous results obtained for the entire mixtures. The B8-1413 isolate from a Weddell seal sample from the Antarctic showed a 8 degrees C value between the two technical products. Although a source appointment to the one or the other product was not possible, this example indicates that long range transport to the Antarctic and by uptake and food-chain bioaccumulation of B8-1413 in seals did not change the delta C-13 value significantly. The observed differences in one duplicate sample indicate that statistic evaluation of samples used for isotope ratio MS measurements is an important issue. (c) 2006 Elsevier B.V. All rights reserved. [References: 24]